Snow and Ice Melting Cable
Snow and ice melting cables are electric heating cables laid beneath the ground or a metal surface to prevent snow build-up and ic

Snow and Ice Melting Under Concrete keeps the entire surface of an outdoor area free of snow and ice using a 350 W/m² electric heater embedded beneath the concrete.
سعر استرشادي تسليم المصنع إسطنبول، غير شامل الضريبة والشحن والرسوم. محوّل من سعر القائمة بالليرة التركية وفق السعر المبيّن، ويُعتمد نهائياً في عرض السعر.
سعر الصرف بتاريخ: 2026-09-15
Snow and Ice Melting Under Concrete keeps the entire surface of an outdoor area free of snow and ice using a 350 W/m² electric heater embedded beneath the concrete. A whole ramp, a courtyard, a vehicle roadway, a car park entrance, a loading ramp or the flat area in front of a door are all sized with this product. The heater is either TMaxPro cable fixed to the reinforcement mesh or ProMat matting with the cable laid on mesh; both use the same cable, give the same output and have identical prices per square metre. You do not switch the system on and off yourself — a control panel with moisture and temperature sensors brings it in the moment it detects precipitation.
Snow and ice melting under concrete is a system that keeps the entire surface of an outdoor area free of snow and ice with an electric heater embedded in the concrete. You do not clear snow, spread salt or do anything else — the system sees the precipitation through its sensor, comes on, and switches off once the surface is dry.
Ekoline Measures the ground temperature and runs the system below a set threshold. It does not detect precipitation. It is sufficient on small areas and for users who deliberately manage the system by hand.
Proline Evaluates precipitation and temperature together: it runs only while snow is falling and the surface is wet. Sensor-driven control cuts energy costs by up to 40%. This is the right tier for most full-area installations.
Maxline Uses the same sensing logic as Proline, but with industrial-grade equipment. It is the choice for high connected loads, multi-zone control, commercial sites that must run without interruption, and areas over 30 m².
| Property | Value |
|---|---|
| Product, application, output | Full-area snow and ice melting system under concrete · TMaxPro cable + fixing strip or ProMat ready-made matting · 350 W/m²same cable, same output and same price per square metre in both types |
| Heated area and connected load | 4 – 50 m² · from 1,400 W to 17,500 Wabove 50 m² calculated project by project |
| Supply and protection | 220 – 240 V AC, 50 Hz · IP67 · two layers of polymer insulation · continuous earth protection and screening · 30 mA residual current device mandatory · three-phase supply and phase balancing above 30 m² |
| Concrete and insulation | 6 – 8 cm below the surface · recommended slab 10 – 13 cm · sub-base insulation at least R-10on an uninsulated slab, downward loss approaches 20% |
| Laying rules | Fixed to the reinforcement mesh with plastic clips at 0.9 – 1.2 m intervals · at least 15 cm from the slab edge · runs must not cross or overlap · sensor conduit between two runs, at least 1.3 cm clear of the cabledo not use wire ties |
| Control | Ekoline temperature sensor only · Proline ISITMAX panel with moisture + temperature sensors · Maxline Eberle panel with moisture + temperature sensors · run-on 30 – 120 minutesthe control panel is included in the price |
| Operating behaviour | Pre-heating 1 – 2 hours before precipitation · first effect at the surface 30 min – 1 hour · fully clear in 4 – 6 hours in most cases · never run before the concrete has cured for 28 – 30 days |
| Manufacture and warranty | Our own CE-certified production since 1995 · 10-year SafeMax warranty on the heating element · control panel, sensors and fixing strip 2 years |
| Condition | Why the required output rises |
|---|---|
| Suspended slabs, bridges and rooftop car parks with open soffits | Heat escapes in two directions; the underside is also exposed to cold air |
| Altitudes above 1,000 metres | Lower air temperatures and higher snow loads |
| Exposed areas with sustained winds above 6 m/s | Convective loss from the surface increases |
| Regions where the design temperature falls below −15 °C | The heat flux required for melting rises |
| Slabs with no sub-base insulation at all | Close to 20% of the heat produced goes downwards |
Snow and Ice Melting Under Concrete is a CE-certified product of the in-house manufacturing ISITMAX has maintained since 1995; shipping covers the whole of Türkiye. For project calculations, dimension checks and questions during installation, contact us on WhatsApp or at info@isitmax.com.
Snow and ice melting cables are electric heating cables laid beneath the ground or a metal surface to prevent snow build-up and ic
Stair and Building Entrance Heating is a system that keeps outdoor stair treads, landings and the flat area in front of the door f
Ramp Wheel-Track Heating is a snow melting system that keeps only the two strips the vehicle wheels run on free of snow and ice on
صف لنا التطبيق وسنقوم بتحديد مقاس النظام وتسعيره.