ISITMAXElektrische Heizsysteme
Downpipe Heating
Dach- und Dachrinnenheizung

Downpipe Heating

Downpipe heating is a system that prevents snowmelt from the roof from freezing again in the vertical downpipe run and blocking the pipe.

Artikel-Nr.: ISX-YAGMUR-INIS-BORUSU Kategorie: Dach- und Dachrinnenheizung
Richtpreis · ab
€45 / $50

Richtpreis ab Werk Istanbul, zzgl. MwSt., Fracht und Zoll. Umgerechnet vom TRY-Listenpreis zum angegebenen Kurs; verbindlich erst im Angebot.
Kurs vom: 2026-09-15

Verfügbare Größen

  • 5 m
  • 10 m
  • 15 m
  • 20 m
  • 30 m
  • 40 m
  • 50 m
  • 60 m
  • 80 m
  • 100 m

Verfügbare Größen

  • Panel to be bought separately
  • Ekoline
  • Proline
  • Maxline

Überblick

Downpipe heating is a system that prevents snowmelt from the roof from freezing again in the vertical downpipe run and blocking the pipe. A single row of HMax self-regulating heating cable is lowered inside the pipe; the cable runs the length of the pipe and lets the water drain away without freezing. It is the last link in the drainage chain: if the water melted at the eaves and in the gutter freezes in the downpipe, the run still blocks. The system runs only when there is a risk of icing, and on runs longer than 20 metres it is managed from a control panel.

The downpipe is the coldest part of the roof drainage: it runs exposed along the outside of the building, catches the wind and has no source of heat to warm the water standing inside it. A thin layer that freezes overnight thickens steadily, the bore of the pipe narrows, and at some point the run closes completely.

Auf einen Blick

The cable runs inside the pipeIn downpipe heating the HMax self-regulating cable is lowered through the mouth of the pipe; there is no need to remove the pipe or to make any additional fixings to the facade.
A single measurement: the total lengthNumber of pipes × pipe height = total length. The price per metre is 482 ₺, with no other multiplier.
Up to 20 metres a panel is not mandatoryShort runs are switched on and off from their own fuse; above 20 m a panel is essential.
10-year warranty on the heater run10 years SafeMax on HMax cable; 2 years on the panel, sensor and installation accessories.

Einsatzbereiche

Ekoline · 24,480 ₺

With temperature sensor

Ekoline · 24,480 ₺ It switches the run on when the air drops below a set threshold and off when it rises. It is sufficient in house and villa applications.

Proline Roof · 41,600 ₺

With temperature and moisture sensors

Proline Roof · 41,600 ₺ If there is no risk of icing in the air, it does not run even in the cold. On commercial buildings and long runs it lowers the operating cost markedly.

Maxline Roof · 62,080 ₺

EBERLE regulator and sensors

Maxline Roof · 62,080 ₺ It works on the same logic as Proline; the regulator and sensors are EBERLE. It is the choice on industrial projects and those with a specification.

Technische Daten

PropertyValue
Product type, code, size rangeDownpipe heating system, RoofMax · ISX-YAGMUR-INIS-BORUSU · 5 – 100 m total length
Heater typeHMax self-regulating cable, single rowthe same cable as the one used inside the gutter
Cable powerHMax30 at 30 W/m in metal pipe · HMax20 at 20 W/m in PVC pipeboth powers are the same price; the pipe type is stated on the order
Price per metre482 ₺/mexcluding VAT, panel separate
Cable length requiredNumber of pipes × pipe heightthere is no allowance or correction factor
InstallationLowered inside through the top mouth of the pipethere is no need to remove the pipe or to fix anything to the facade
Cutting on sitePossible thanks to the self-regulating construction; the cable does not overheat if it overlaps itself
ControlFuse or panel up to 20 m · panel mandatory above 20 mEkoline temperature · Proline and Maxline temperature + moisture
Warranty10 years SafeMax on the heater run2 years on the panel, sensor and installation accessories

Auswahlhilfe

How is the length calculated for downpipe heating?

BuildingCalculationTotal lengthStep to select
Villa, 2 downpipes2 × 6 m12 m15 m
Apartment building, 4 downpipes4 × 8 m32 m40 m
Commercial block, 6 downpipes6 × 10 m60 m60 m

Ist dies das richtige Produkt?

Passend, wenn

  • Your downpipes block, crack or overflow and form a layer of ice on the facade in winter.
  • Your pipe material is galvanised steel, copper, aluminium, steel or PVC — there is a separate cable type for metal and for PVC, at the same price.
  • Eaves and gutter heating is already in place or planned and you want to complete the last link in the drainage chain.
  • You will apply it to existing pipes afterwards; the cable is lowered through the top mouth of the pipe and there is no need to remove it.
  • If the run exceeds 20 metres you are able to buy a control panel; on short runs, control from the fuse is enough.

Nicht geeignet, wenn

  • If the ice forms inside the gutter — downpipe heating alone is not enough; Roof Gutter and Valley Heating heats the base of the gutter.
  • If the problem is the ice dam and icicles at the roof edge — Roof Edge Eaves Heating heats a band along the roof edge.
  • If a fire sprinkler line or a pressurised installation pipe is freezing — Fire Sprinkler Line Frost Protection mounts the cable on the outside of the pipe and covers it with insulation.
  • If you are heating a floor, ramp or building entrance — Snow and Ice Melting Under Concrete and Stair and Building Entrance Heating are separate products.
  • If siphonic drainage outlet heating is required — this calculation is project-based and falls outside the steps on this page.

Installation

  1. PreparationThe mouth of the pipe and the outlet are cleared of leaves and sediment; no blockage is left that would stop the cable going down. The pipe type (metal or PVC) is confirmed.
  2. Lowering the cableThe cable is lowered inside through the top mouth of the pipe and travels to the bottom under its own weight. It is fixed at the top mouth with an installation accessory. If the gutter run is heated as well, the junction between them is arranged.
  3. Sensor and electrical connectionThe temperature sensor is placed at a point that stays in shade and the moisture sensor on an exposed surface. A qualified electrician makes the panel connection and the supply line.
Who should install it? On short downpipes reached from the ground floor your own electrician can carry out the work. On tall facades and multi-block complexes, installation by the company is recommended — facade and roof installation is assessed separately after a survey. No work is done on a facade without safety measures in place.

Bestellung und Lieferung

  1. same dayThe order is placed by selecting the total length and the panel
  2. 1 working dayThe number of pipes, their height and their material are confirmed
  3. 1–2 working daysThe cable is prepared to size and passes a quality test
  4. 2–4 working daysHandover to the carrier, a tracking number and shipping throughout Türkiye
  5. as requiredTechnical support with installation and setting the panel

Garantie und Support

Yes. Up to 20 metres the run can be switched on and off from its own fuse; you may still choose a panel at this length if you wish. Above 20 metres a panel is mandatory and an installation without one falls outside the warranty. If there is also an eaves or gutter run on the same roof, choose the panel on one product only — a single panel manages all three runs.

Häufige Fragen

Is downpipe heating enough on its own?
Downpipe heating is the last link in the drainage chain. If your gutter freezes, the water cannot reach the downpipe in the first place; in that case the gutter run needs heating as well. For complete protection it is recommended that the eaves, gutter and downpipe be planned together.
How do I calculate the length?
Number of pipes × pipe height. Four pipes of 8 metres come to 32 metres; you select 40 metres, the next step up in the selector. There is no allowance or correction factor; any surplus cable is cut on site.
Should I choose HMax30 or HMax20?
HMax30 (30 W/m) is used in metal pipes (galvanised steel, copper, aluminium, steel) and HMax20 (20 W/m) in PVC and plastic pipes. The lower power is chosen for PVC because a high surface temperature can deform plastic. The two are the same price — you need only state the pipe type on the order.
Does the cable run inside the pipe?
Yes. In downpipe heating the cable is lowered inside through the top mouth of the pipe and travels to the bottom under its own weight. No fixing to the outside of the pipe and no removal or replacement of the pipe is needed; it is applied to existing pipes afterwards.
Can I really use it without buying a panel up to 20 metres?
Yes. Up to 20 metres the run can be switched on and off from its own fuse; you may still choose a panel at this length if you wish. Above 20 metres a panel is mandatory and an installation without one falls outside the warranty. If there is also an eaves or gutter run on the same roof, choose the panel on one product only — a single panel manages all three runs.

Ähnliche Produkte

Dach- und Dachrinnenheizung

Roof Edge Eaves Heating

The eaves heating system is a snow and ice melting solution that prevents the ice dam that forms at the edge of pitched roofs, the

ab €175 $205Produkt ansehen →

Angebot anfordern

Beschreiben Sie die Anwendung — wir legen das System aus und erstellen ein Angebot.