Eberle DIN-Rail Thermostats and Control Sets
Eberle DIN-rail thermostats are control units that manage snow and ice melting and frost protection heating automatically.

A heating system temperature sensor is the component that passes the measured temperature to the thermostat.
سعر استرشادي تسليم المصنع إسطنبول، غير شامل الضريبة والشحن والرسوم. محوّل من سعر القائمة بالليرة التركية وفق السعر المبيّن، ويُعتمد نهائياً في عرض السعر.
سعر الصرف بتاريخ: 2026-09-15
A heating system temperature sensor is the component that passes the measured temperature to the thermostat. Without a sensor the system cannot manage itself: the cable either runs continuously or never comes on at all. Two 10K NTC sensor types are offered here, working with ISITMAX HTEC thermostats and Ekoline / Proline control panels.
A heating system temperature sensor contains an NTC thermistor: an element whose resistance falls as temperature rises. The thermostat or control panel continuously reads that resistance between the two leads and calculates the corresponding temperature. When the reading falls below the threshold set on the device, the heating circuit is energised; when it rises above it, the supply is cut.
A sensor connected to the control panel, with a 4 m lead and a 2-core connection. It is used in systems where measurement at a single point is sufficient, such as snow and ice melting, roof and gutter heating and floor heating.
A polyethylene-sheathed sensor with a 3 m mounting lead. It is taped to the surface of the heated pipe and reads the temperature at the point of contact. Choose this type in pipeline frost protection applications where you want to see the actual pipe temperature.
| Application | Sensor type | Where it is fitted |
|---|---|---|
| Pipeline frost protectionheat tracing | Pipe surface | To the bare pipe surface, opposite the cable |
| Tank and valve heating | Pipe surface | At the coldest part of the surface, beneath the insulation |
| Roof, gutter and downpipe | Panel type | At the shaded point where ice first forms |
| Ramp and outdoor ground snow melting | Panel type | In the slab, at cable level, before the pour |
| Under-concrete floor heating | Panel type | In the screed, midway between two cable runs |
The choice between the two types comes down to whether what you want to measure is a surface or an ambient. The table below summarises which type is used in the most common applications.
| Property | Panel type | Pipe surface |
|---|---|---|
| Sensing element | 10K NTC | 10K NTC |
| Cable length | 4 m | 3 m |
| Number of cores | 2 | — |
| Sheath material | — | Polyethylene |
| Operating temperature range | — | -55 °C … +60 °C |
| Device it connects to | HTEC thermostat / control panel | HTEC thermostat / control panel |
| Barcode | 8683498835235 | 8683498831169 |
The system must be de-energised while the connection is made. Have the connection made by a qualified electrician.
Every heating system temperature sensor carries a 2-year manufacturer warranty. ISITMAX has manufactured its own electric heating products since 1995; manufacturing is CE certified. Our technical support team is available Monday–Saturday 09:00–17:00. If you are unsure about placing the sensor at the right point, share your system diagram with us. The warranty starts automatically with the invoice; full conditions are on the SafeMax Warranty Programme page.
Eberle DIN-rail thermostats are control units that manage snow and ice melting and frost protection heating automatically.
The Eberle temperature and moisture sensor is the component that decides when a snow melting or de-icing system runs.
A heat trace junction box is the point, exposed to outdoor conditions, where the heating cable is connected to the supply.
Self-regulating heating cables are cut to length on site.
صف لنا التطبيق وسنقوم بتحديد مقاس النظام وتسعيره.