ISITMAXأنظمة التدفئة الكهربائية
Cold Store Floor Heating Mat
التتبع الحراري للأنابيب والخزانات

Cold Store Floor Heating Mat

A cold store floor heating mat is an electrical floor protection system laid beneath concrete that prevents the ground under the floor of a store running at −30 °C to −40 °C from freezing…

رقم الصنف: 8683498834450 الفئة: التتبع الحراري للأنابيب والخزانات
سعر استرشادي · ابتداءً من
€30 / $35

سعر استرشادي تسليم المصنع إسطنبول، غير شامل الضريبة والشحن والرسوم. محوّل من سعر القائمة بالليرة التركية وفق السعر المبيّن، ويُعتمد نهائياً في عرض السعر.
سعر الصرف بتاريخ: 2026-09-15

نظرة عامة

A cold store floor heating mat is an electrical floor protection system laid beneath concrete that prevents the ground under the floor of a store running at −30 °C to −40 °C from freezing and that freezing from lifting the slab. TMax cable is used as the heater; the mat is that cable arranged at the correct spacing on a carrier at the factory. An average of 4 metres of cable goes into each 1 m², and an Ekoline control unit is included with the system. The mat is made 50 cm or 100 cm wide, with the length specific to the project; at least 5 cm of fine, aggregate-free concrete or screed is poured over it.

The EasyMat mat is TMax heating cable arranged at the correct spacing on a carrier at the factory. The cable itself does not change — what changes is how it arrives on site. In free cable form you set the laying spacing on site; on the mat that spacing is fixed at the factory. This is where the real value of the cold store floor heating mat lies: the roll is unrolled and laid side by side, the laying time is markedly shorter and the margin for error on site is lower.

لمحة سريعة

4 metres of TMax per 1 m²In mat form the cable is arranged on a carrier at the factory; the laying spacing cannot be disturbed on site.
50 and 100 cm wide, length specific to the projectThe roll is unrolled and laid side by side. It is dimensioned to your store area.
Ekoline control unit includedIt reads from the floor sensor and switches on and off automatically. The recommended set temperature is +2 °C.
10-year warranty on the matOur own manufacture since 1995. 2-year warranty on the panel and sensor.

أين يُستخدم

Mat 50 cm wide

For narrow areas and detailed applications

Mat 50 cm wide 50 cm wide, with the length specific to the project. It turns more easily in narrow corridors and small compartments; this width is also used to cover the narrow strips at the edge of an area.

Mat 100 cm wide

For wide areas and quick installation

Mat 100 cm wide 100 cm wide, with the length specific to the project. It covers the same area with fewer rolls, so it leaves fewer joints and the laying finishes faster.

المواصفات الفنية

PropertyValue
Product and useCold store floor heating mat beneath concrete · TMax heating cable in EasyMat mat formthe outdoor floors of cold stores, ice houses and ice skating rinks
Cable length requiredan average of 4 metres of cable per 1 m²in a redundant system, an average of 8 metres per 1 m² in two independent runs
Mat dimensionsWidth 50 cm or 100 cm · length specific to the projectthe carrier may be cut at turns; the cable may not
Concrete to be poured over itAt least 5 cm of fine, aggregate-free concrete or screedconcrete containing crushed stone is not used
Operating environmentBeneath the floor of cold stores running at −30 °C to −40 °Cits purpose is not to heat the store but to hold the ground beneath the floor above freezing point
ControlEkoline control unit · digital temperature display · adjustable set temperature, recommended +2 °C · automatic switching on and off · low and high temperature alarmit is possible to move up to the Proline and Maxline steps
SensorFloor temperature sensor with a 3 metre lead · placed between two runs in installation conduitone per panel
Electrical protectionFed through a 30 mA residual current devicethe relay, the supply line and the electrical labour are not included in the price
Consumables charge15 per centcarrier material and factory mat production labour
Manufacture and warrantyOur own manufacture since 1995 · 10-year warranty on the mat · 2-year warranty on the control unit, thermostat and sensor

دليل الاختيار

Mat or cable?

AspectEasyMat mattingTMax cable
How it arrives on siteThe cable arranged on a carrier at the factory, in a rollCable at the calculated length, with its fixing strip
Laying spacingFixed at the factory; cannot be changed on siteSet on site; can be tightened around obstacles
Suitable geometryRegular, wide floors close to a rectangleIrregularly shaped, narrow or angular floors
Laying timeThe roll is unrolled; markedly shortYou work run by run; it takes longer
Consumables charge15 per cent — carrier material and factory assembly labourNone; it comes with its fixing strip
Cable per 1 m²An average of 4 metresAn average of 4 metres

هل هذا المنتج مناسب لك؟

مناسب عندما

  • You are building or renewing a cold store, ice house or ice rink and want to prevent the ground beneath the floor from freezing and damaging the foundation.
  • The area to be heated is regular and wide — the mat roll is unrolled and laid side by side, and the laying time is markedly shorter.
  • You want the laying spacing to be fixed at the factory, so the margin for error on site is low.
  • You are able to pour at least 5 cm of fine, aggregate-free concrete or screed over the mat.
  • You operate a critical store (pharmaceuticals, vaccines, high-value food) and are considering the redundant system option.

غير مناسب عندما

  • If your area is irregularly shaped, narrow or angular — the mat has to be cut frequently; the Cold Store Floor Heating Cable, the free form of the same cable, lets you adjust the laying spacing on site.
  • If you do not want to break up the existing concrete — the mat goes beneath the floor; it cannot be added to the surface afterwards.
  • If the sprinkler line inside the store is freezing — Fire Sprinkler Line Frost Protection is a separate system mounted on the pipe.
  • If you are melting snow and ice outdoors — store floor protection works for frost protection and does not melt snow; for ramps and courtyards, Snow and Ice Melting Under Concrete is the right product.
  • If you have to pour concrete containing crushed stone — the mat needs fine, flowing, aggregate-free concrete over it; if that is not possible, choose the cable system.

التركيب

Installing a cold store floor heating mat runs hand in hand with the floor construction, and there is no going back once the concrete is poured. Your own team can do the laying; the connection to the panel and the supply line must be left to a qualified electrician.

Do not skip the final check before the concrete is poured. Once the mat is in the concrete, the only way to put something right is to break up the slab. When the laying is complete, check that the runs do not overlap, that cuts in the carrier have not damaged the cable, and that the sensor conduit is in place.

الطلب والتسليم

  1. at the time of orderThe order is placed by selecting the system that matches your store's square metres from the selector
  2. after the sketchThe floor sketch arrives; the net area, the mat width and the decision on a redundant layout are confirmed
  3. production stageThe mat is made to a length specific to the project and the cold leads are brought out along the panel route
  4. dispatchHandover to the carrier, shipping throughout Türkiye with a tracking number
  5. as requiredTechnical support at the laying, sensor positioning and panel commissioning stages

الضمان والدعم

The warranty on a cold store floor heating mat splits into two items: the heating element that stays beneath the concrete, and the control equipment in an accessible position. With the floor heating experience we have carried on since 1995, you can use ISITMAX products with confidence. For project calculations, dimension checks and questions during installation you can reach us on WhatsApp and at info@isitmax.com.

الأسئلة الشائعة

Why is there a consumables charge?
The 15 per cent consumables charge covers the labour of assembling the cables onto the mat at the factory and the carrier material. There is no such item in free cable form; it is the cost of the production labour that the mat form brings with it.
Can the mats be cut?
The carrier can be cut but the cable cannot. This is why the mat is made to a size specific to the project. At turns only the carrier mesh is cut, and the cable continues without a break.
What should the minimum concrete thickness be?
At least 5 cm of fine, aggregate-free concrete or screed must be poured over the mat. Concrete containing crushed stone is not used; coarse aggregate puts mechanical strain on the mat's carrier and on the cable.
Can it be used on ice rinks?
The same logic applies in ice houses and ice skating rinks: the aim is not to heat the surface but to hold the ground beneath the slab above freezing point. We handle applications of this kind as projects.
How much cable is needed per 1 m²?
In the standard layout an average of 4 metres of TMax cable goes into 1 m². In a redundant system an average of 8 metres of cable is laid over the same area, in two independent runs.

منتجات ذات صلة

التتبع الحراري للأنابيب والخزانات

Pipeline Frost Protection System

A pipeline frost protection system keeps a line working through the winter by running a heating cable along the outside of the pip

ابتداءً من €10 $10عرض المنتج →
التتبع الحراري للأنابيب والخزانات

Industrial Tank Heat Tracing

Industrial tank heat tracing is a heating cable system wrapped around the body of storage and process tanks: it prevents the liqui

ابتداءً من €1 280 $1 480عرض المنتج →

اطلب عرض سعر

صف لنا التطبيق وسنقوم بتحديد مقاس النظام وتسعيره.