ISITMAXأنظمة التدفئة الكهربائية
Gas Cylinder Heating Jacket
السخانات المرنة والأغطية الحرارية

Gas Cylinder Heating Jacket

The gas cylinder heating jacket is a flexible heater that wraps the body of upright cylindrical vessels such as gas cylinders and maintains the temperature of the liquid or gas inside.

رقم الصنف: 8683498834504 الفئة: السخانات المرنة والأغطية الحرارية
سعر استرشادي · ابتداءً من
€430 / $495

سعر استرشادي تسليم المصنع إسطنبول، غير شامل الضريبة والشحن والرسوم. محوّل من سعر القائمة بالليرة التركية وفق السعر المبيّن، ويُعتمد نهائياً في عرض السعر.
سعر الصرف بتاريخ: 2026-09-15

المقاسات المتاحة

  • 50 cm × 15 cm, 7 l
  • 86 cm × 14 cm, 18 l
  • 87 cm × 20 cm, 34 l
  • 93 cm × 20 cm, 34 l
  • 94 cm × 14 cm, 19 l

نظرة عامة

The gas cylinder heating jacket is a flexible heater that wraps the body of upright cylindrical vessels such as gas cylinders and maintains the temperature of the liquid or gas inside. It is used to recover the pressure that drops in the cold in LPG, propane and acetylene cylinders, and to prevent chemical, food and pharmaceutical liquids from freezing and becoming viscous. The jacket is tightened around the cylinder with a strap and steel buckle; it is made in five standard sizes from 7 litres to 34 litres, with power between 200 and 600 W. Its precise digital thermostat is set between 0 and 90 °C, and the safe upper limit of the jacket is 60 °C. It is the member of the tank and drum heating family that addresses the smallest vessels.

لمحة سريعة

Integrated digital thermostatThe control unit comes with the jacket and is set on a 0–90 °C scale. No separate thermostat, sensor or panel is required.
Five standard sizes, 200–600 WReady-made sizes for cylindrical vessels from 7 litres to 34 litres. Custom manufacture for a diameter not on the list.
Carbon fibre insulation, Kevlar stitchingNon-combustible inner sheath, waterproof polyester outer sheath, steel buckle and strap. For frequent fitting and removal.
CE certified, 2-year warrantyOur own production since 1995. Shipping throughout Türkiye.

أين يُستخدم

P600/7 — 7 L

Small-volume cylinders, 200 W

A 500 × 150 mm jacket. For small gas cylinders and laboratory and sample vessels. The model that draws the least electricity and heats up fastest.

P600/18 ve P600/19 — 18–19 L

Medium-sized cylinders, 400 W

Jackets of 860 × 140 mm and 940 × 140 mm. The power and band height are the same and only the length differs: for two different body diameters within the same volume class.

P600/34 ve P600/34/2 — 34 L

Large-volume cylinders, 600 W

Jackets of 870 × 200 mm and 930 × 200 mm. The band widens to 200 mm and the heat spreads over a broader belt. Two lengths, for short-and-wide and long-and-narrow body shapes.

IndustryApplication and the benefit it provides
Gas cylindersKeeping the pressure steady in LPG, propane and acetylene cylinders. In the cold the cylinder pressure drops and the flow breaks down; by holding the gas at the ideal temperature, the jacket keeps the flow continuous.
ChemicalsPreventing chemicals and gases from becoming viscous and freezing at low temperatures; keeping the production process safe and efficient.
Food and beveragePreventing products such as oil, syrup and honey from solidifying. Viscous foodstuffs keep their fluidity on production lines.
PharmaceuticalsHolding sensitive liquids and solutions at a steady temperature. Pharmaceutical compounds retain their chemical structure.
Industrial processesMaintaining the fluidity of paint, coating material and similar liquids; because the material does not solidify, the process continues without interruption.

المواصفات الفنية

PropertyValue
Product typeGas cylinder heating jacket, P600 seriesFlexMax – flexible heating products
Max. jacket temperature60 °C
ThermostatPrecision digitally controlled thermostat and control unit, 0–90 °Ccomes integrated with the jacket
Mains supply230 V
Power range200–600 W200 W / 400 W / 600 W
Inner linerSilicone / glass fibrenon-combustible
Outer linerWaterproof polyester fabricstain-resistant
Thermal insulationCarbon fibrespecial double layer
Heating elementAluminium-layered, silicone-insulated glass fibre braidfitted with Kevlar stitching
Heating zoneSingle-zonethe whole surface heats up
Protection classII
Lead length2 metres
BuckleSteel buckle and heavy-duty polyester strapiron clasps
Jacket sizes500 × 150 · 860 × 140 · 940 × 140 · 870 × 200 · 930 × 200 mm
Suitable cylinders7, 18, 19 and 34 L cylindrical vesselscircumference between 500 mm and 940 mm
Custom size and outputYes, optional
ConformityCE-certified manufacture
Warranty2-year manufacturer warranty
Main stock code8683498834504a separate barcode for each size, in the size table

دليل الاختيار

Cylinder, canister or drum?

AspectGas cylinder jacketBucket jacketCanister jacketDrum jacket
Vessel shapeA narrow, upright cylinder of constant cross-sectionTapered, wide-mouthedA wide-bodied canisterA standard metal drum
Volume range7–34 L19 LUp to 120 L200 L
Its main jobMaintaining pressure and fluidity in pressurised gas and sensitive liquids200–600 W, jacket length 500–940 mmMaintaining temperature in a small volumeReducing viscosityComplete thawing, maintaining temperature

هل هذا المنتج مناسب لك؟

مناسب عندما

  • You do not want the gas flow to stop in an LPG, propane or acetylene cylinder whose pressure drops in the cold.
  • You need to keep a chemical, food or pharmaceutical liquid in a cylindrical vessel from freezing and becoming viscous.
  • The circumference of your cylinder is between 500 and 940 mm, or you are open to having one made to measure.
  • Your target temperature is below 60 °C and you want to set it precisely.
  • You are looking for a set that works without getting into separate sensors, thermostats and panels.

غير مناسب عندما

  • If you have a 1000 litre IBC tank — a cube-bodied tank cannot be wrapped with this jacket; the heating jacket for IBC tanks is cut to that geometry.
  • If your vessel is larger than 34 litres — the largest jacket length is 940 mm. Canisters up to 120 litres are heated with the canister heating jacket, and 200 litre drums with the drum heating jacket.
  • If your vessel is a tapered, wide-mouthed bucket — a cylindrical cut will not sit properly even at 19 litres; the bucket heating jacket is the right product.
  • If a surface temperature above 60 °C is required: the maximum temperature of the jacket is 60 °C.
  • If you are heating pipe, valves or process equipment: the heated pipe and valve jacket is made for those geometries.

التركيب

Yes — the jacket needs no tools and is fitted by one person. Wrap the jacket around the body of the cylinder, bring the ends together, then pass the polyester strap through the steel buckle and tighten it. It is important that the inner surface contacts the body at every point; if an air gap is left, heat transfer falls and the jacket's own surface temperature rises unnecessarily. Clean the outside of the cylinder before wrapping and leave no caked-on material or label residue.

الطلب والتسليم

  1. same dayYou select the size and place your order
  2. 1 working dayConfirmation of size and stock, and a circumference check if needed
  3. 1–2 working daysHandover to the carrier and tracking number
  4. 1–3 working daysDelivery throughout Türkiye
  5. as requiredSupport with installation and thermostat setup

الضمان والدعم

ISITMAX has manufactured electric heating products in its own facility since 1995. The gas cylinder heating jacket is also our own manufacture; it is part of our flexible heating product line, developed over many years in line with industrial conditions and customer feedback.

الأسئلة الشائعة

What temperature does the gas cylinder heating jacket reach?
The maximum temperature of the jacket is 60 °C. The precise digital thermostat on the control unit is set on a scale from 0 to 90 °C; you must keep your operating temperature below 60 °C. This range is enough to hold many liquids and gases safely.
Do I also need to buy a thermostat or control panel?
No. A digital control unit comes integrated in all models, and the jacket runs by connecting to the 230 V mains with its 2 metre lead. A separate heating control panel is only needed if you want to manage more than one jacket from a single point.
How do I choose the right size?
Wrap a tape measure around the body of the cylinder to measure its circumference and choose the nearest jacket length: 500, 860, 870, 930 or 940 mm. If you are working from the diameter, divide the circumference by 3.14; a 940 mm length, for example, corresponds to an outside diameter of about 299 mm. Volume is the second criterion: 200 W for 7 litres, 400 W for 18–19 litres, 600 W for 34 litres.
Does it really increase the pressure in a gas cylinder?
The jacket does not increase the pressure — it stops it from falling. In cold weather, as the temperature of the gas inside the cylinder drops, so does the pressure, and the flow weakens. By holding the gas at the ideal temperature the jacket prevents this drop, so the gas flow continues without interruption. This is its most common job on LPG, propane and acetylene cylinders.
How long does it take to heat up?
According to measurements, raising the contents from 10 °C to 50 °C takes about 2 hours on the P600/7, about 6.7 hours on the P600/34 and about 10 hours on the P600/18. These figures vary considerably with the type of contents, the starting temperature, the fill level and the ambient temperature; a cylinder full of gas and one full of liquid do not heat up in the same time.

منتجات ذات صلة

السخانات المرنة والأغطية الحرارية

Mirror Heating Film

The mirror heating film is a 1 mm thick carbon heating film bonded to the back of bathroom, hotel, spa and hammam mirrors, warming

ابتداءً من €10 $10عرض المنتج →
السخانات المرنة والأغطية الحرارية

Industrial Canister Heating Jacket

The canister heating jacket is a flexible electric heating wrap that encloses a 120 litre canister from the outside, rated at 800

ابتداءً من €450 $520عرض المنتج →

اطلب عرض سعر