Pipeline Frost Protection System
A pipeline frost protection system keeps a line working through the winter by running a heating cable along the outside of the pip

A cold store floor heating cable is an electrical system that holds the ground beneath the store's concrete slab above freezing point.
Richtpreis ab Werk Istanbul, zzgl. MwSt., Fracht und Zoll. Umgerechnet vom TRY-Listenpreis zum angegebenen Kurs; verbindlich erst im Angebot.
Kurs vom: 2026-09-15
A cold store floor heating cable is an electrical system that holds the ground beneath the store's concrete slab above freezing point. The aim is not to heat the inside of the store — it is to stop the ground beneath a space running at sub-zero temperatures from freezing, expanding and lifting the slab from below. The heater used is TMax cable of constant 17 W/m: an average of 4 metres of cable is laid per 1 m², and the system comes together with an Ekoline control unit. The cable form lets you adjust the laying spacing on site in stores whose floor area is narrow, angular or irregular.
A cold store floor heating cable is an electric heating element buried beneath the store's slab that holds the ground above freezing point. ISITMAX manufactures TMax cable of constant 17 W/m for this job; the cable is prepared at the length calculated for the site, comes together with its fixing strip and is laid before the concrete is poured.
The cable comes at the calculated length together with its fixing strip; you set the spacing on site. It is the only answer when you need to work around obstacles such as column bases, machine plinths, manhole covers and rack anchors, or to tighten the spacing in critical areas such as doorways. It is also the most flexible form for applications over reinforcement mesh.
The cable is arranged at the correct spacing at the factory on a carrier 50 cm or 100 cm wide. The roll is unrolled and laid side by side, and at turns only the carrier is cut. Because the laying spacing is fixed at the factory, the margin for error on site is low. A consumables charge also applies to the mat form.
| Property | Value |
|---|---|
| Product and use | Cold store floor heating cable · floor frost protection system beneath concrete · cold stores, ice houses and ice rinksit is for floor protection, not for comfort heating |
| Heater | TMax constant-wattage heating cable · 17 W/mthe same cable is also used in EasyMat mat form |
| Cable length required and laying spacing | an average of 4 metres of cable per 1 m² · roughly 25 cm laying spacingin a redundant system, 8 metres per 1 m² in two independent runs |
| Store operating temperature | Used at internal store temperatures down to −40 °C |
| Floor set temperature | Adjustable · recommended value +2 °C |
| Installation position | Fixed onto the thermal insulation board or to the reinforcement mesh · at least 5 cm of screed or floor mortar over itthe runs must not cross, overlap or be brought close to one another |
| Control | Ekoline control unit · digital display · adjustable set temperature · automatic switching on and off · low and high temperature alarm · 16 A contactor outputthe control unit is included in the price |
| Sensor | Floor temperature sensor with a 3 metre lead · inside installation conduit, midway between two heating runsbecause it is inside conduit, it can be replaced without breaking up the concrete |
| Electrical protection | Fed through a 30 mA residual current devicethe relay, the supply line and the electrical labour are not included in the price |
| Maintenance | The cable beneath the concrete has no moving parts · an annual check of the control unit is recommended |
| Manufacture and warranty | Our own manufacture, carried on since 1995 · 10 years on the cable · 2 years on the control unit, thermostat and sensor |
| Store floor (net) | Standard single-run cable | Redundant system cable |
|---|---|---|
| 25 m² | 100 metres | 200 metres |
| 50 m² | 200 metres | 400 metres |
| 100 m² | 400 metres | 800 metres |
| 250 m² | 1,000 metres | 2,000 metres |
Installing a cold store floor heating cable runs hand in hand with the concrete pour and there is no going back — once the pour is finished, reaching the cable means breaking up the concrete. Your own team can do the laying; the connection to the control unit and the supply line must be left to a qualified electrician.
With the knowledge and experience in floor heating systems we have built up since 1995, we design and manufacture ourselves the floor heating systems best suited to cold stores. For project calculations, dimension checks and questions during installation you can reach us on WhatsApp and at info@isitmax.com.
A pipeline frost protection system keeps a line working through the winter by running a heating cable along the outside of the pip
Industrial tank heat tracing is a heating cable system wrapped around the body of storage and process tanks: it prevents the liqui
A silicone-insulated pipe heating cable (heat trace) is a heating cable wrapped around or run along the surface of pipe and tank l
HMax is a self-regulating heating cable made to prevent pipelines freezing.
Beschreiben Sie die Anwendung — wir legen das System aus und erstellen ein Angebot.