Industrial Electric Drum Heating Jacket 200 L / 215 L
The drum heating jacket is a flexible electric heater that wraps the full body of 200, 215 and 220 litre drums.

The IBC tank heating jacket is an industrial heating jacket that wraps a 1,000 litre caged IBC tank on all four sides.
Ориентировочная цена на условиях EXW Стамбул, без НДС, фрахта и пошлин. Пересчёт из прайса в TRY по указанному курсу; подтверждается в коммерческом предложении.
курс на: 2026-09-15
The IBC tank heating jacket is an industrial heating jacket that wraps a 1,000 litre caged IBC tank on all four sides, heats it evenly at a low surface loading and holds the temperature with a digital control unit. Its purpose is to bring raw material to a pumpable viscosity or to stop it freezing in the cold. The jacket is a single 4,400 × 1,000 mm piece, secured with strapping and a steel buckle, and can be removed and fitted to the next tank. There are three power ratings — 1,600 W, 2,400 W and 3,200 W — and the choice is determined by the job you are doing, not by the tank volume.
For holding a tank stored over winter above its critical temperature and preventing the raw material freezing. Intended for protection rather than heating; it draws at most 1.6 kWh per hour.
For raw materials that thicken in the cold, such as honey, vegetable and mineral oils, molasses and resin; this is the most frequently chosen rating. The theoretical time to raise 1,000 litres of water-based contents by 30 °C is 14.5 hours.
For production that needs a high target temperature and short cycles; it completes the same 30 °C rise in a theoretical 10.9 hours.
| Industry | Typical application |
|---|---|
| Chemicals and petrochemicals | Maintaining flowability in resins, adhesives, solvents and chemical raw materials |
| Food | Keeping honey, glucose, syrup and vegetable oil liquid; heating molasses to 40 °C |
| Pharmaceuticals and cosmetics | Holding production liquids at a constant temperature, processing SLES paste at 25–35 °C |
| Construction | Preventing concrete admixtures thickening in the cold, bitumen emulsion |
| Lubricants | Keeping oil stored in an IBC tank pumpable through the winter |
| Property | Value |
|---|---|
| Product type | Industrial IBC tank heating jacket, FlexMax range |
| Tank capacity | 1,000 litres |
| Container type | Caged IBC |
| Dimensions | 4400 × 1000 mm |
| Power ratings | 1.600 / 2.400 / 3.200 W |
| Mains voltage | 230 V |
| Control | Integrated digital control unitcurrent and target temperature display, red ready LED |
| Thermostat / control range | 0 – 120 °C |
| Heating zone | Single zone, the whole surface heats |
| Heating element | Kevlar-stitched onto aluminium-coated glass fabric, silicone insulated |
| Inner liner | Silicone / glass fibre |
| Thermal insulation | Carbon fibretechnical carbon insulation — does not shed fibres |
| Outer liner | Waterproof polyester fabricchemical resistant, high tensile strength |
| Fastening | Strapping, steel buckle and hook-and-loop closureheavy-duty polyester webbing |
| Electrical safety | Double insulatedrequires no earth connection; supplied through a residual current device |
| Protection class | II |
| Cable length | 3 metres |
| Storage | Foldabledo not wrap tighter than 150 mm diameter |
| Optional | Insulated top cover with pump inlet · custom sizes and custom power ratings made to order |
| Conformity | CE-certified manufacture |
| Warranty | 2-year manufacturer warranty |
| Stock code | 8683498832050separate barcode per power rating |
| Model | Heat output | Purpose | Jacket dimensions | Barcode |
|---|---|---|---|---|
| P1600 | 1.600 W | Frost protection, low temperaturepractical upper temperature 40 °C in the previous catalogue | 4400 × 1000 mm | 8683498832074 |
| P2400 | 2.400 W | Honey, oils and viscous liquidspractical upper temperature 60 °C in the previous catalogue | 4400 × 1000 mm | 8683498832067 |
| P3200 | 3.200 W | Process heating, high targetpractical upper temperature 85 °C in the previous catalogue | 4400 × 1000 mm | 8683498836768 |
Yes — the jacket needs no tools; it is wrapped around the tank, the straps are fed through the steel buckle and fastened with the hook-and-loop closure. Make sure the surface sits against the tank wall and cage at every point; any air gap reduces heat transfer. Then set the control unit to the target temperature and plug the lead into a 230 V circuit with residual current protection. The red LED shows it is ready to run; the current and target temperatures are shown together on the display, and once the target is reached the unit cycles at that point.
ISITMAX has manufactured electric heating products in its own facility since 1995, with more than 15 years of manufacturing experience in flexible heating systems. The industrial IBC tank heating jacket is also our own CE-certified production and part of the FlexMax flexible heating range.
The drum heating jacket is a flexible electric heater that wraps the full body of 200, 215 and 220 litre drums.
The mirror heating film is a 1 mm thick carbon heating film bonded to the back of bathroom, hotel, spa and hammam mirrors, warming
The canister heating jacket is a flexible electric heating wrap that encloses a 120 litre canister from the outside, rated at 800
The industrial drum heating cabinet is a wheeled drum heating unit that encloses a single 200–220 litre drum in an insulated.
Опишите задачу — мы подберём систему и дадим цену.